Description: Dynamic Mixer, 2000Ul, Built-In Accessory For 5110/5160 Pump.
Catalog Number: 76493-072
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Sample Rack, Standard, (1.5Ml X 120). Same Rack As Standard Equipped Rack With 5210/5260 Autosampler without Thermostat.
Catalog Number: 76493-094
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Thermo Cell For 5430 Dad. With Thermo Function. Flow Cell Control Unit For 5430 (P/N: 892-0600) Is Required.
Catalog Number: 76493-158
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: THF kit, For 5260. With Wash Pump For Hexane/Thf, Injection Valve(70Mpa) And Parts(Include P/N 892-0811 Wash Pump (For Hexane)).
Catalog Number: 76493-184
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Cabinet For Solvent Bottles. (Galon Bottle X 2, 500Ml X 3))Power Supply Function For Pump, As, Ifc Board, Detectors.
Catalog Number: 76493-180
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Autosampler, Chromaster 5260, Capacity: 120 Vials X1.5 Ml (Standard), 195 X 1Ml, 72 X 4Ml, 2 X Mtp, Injection Volume: 0.1 ul To 50 ul (100Ul Loop, Standard), Injection Volume Precision: 0.2% Rsd (10-ul Cut Injection)
Catalog Number: 76493-092
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5430 Diode Array DetectorNoise: < 0.5 X 10-5 Au Drift: < 0.5 X 10-3 Au/H Wavelength Range: 190 To 900 Nm
Catalog Number: 76493-146
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5110 PumpAccuracy +/- 1% Or +/- 2 ul/Min, Whichever Is Greater (0.010 To 5.000 Ml/Min)Precision +/- 0.075 % Rsd Or 0.02 Min Sd Maximum Pressure 40 Mpa (0.001 To 5.000 Ml/Min), 20 Mpa (5.001 To 9.999 Ml/Min)
Catalog Number: 76493-058
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5440 Fluorescence Detector, Emission Wavelength: 250 To 900 Nm, Excitation Wavelengths: 200 To 850 NmSignal To Noise Ratio: Greater Than Or Equal To 1200: 1 For Raman Band Of Water At 350 Nm (Baseline Method), Wavelength Accuracy: +/- 3 Nm
Catalog Number: 76493-174
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5260 Autosampler With Cooling, Setpoint Range (1-45 deg C, 1 deg C Steps)* Vials (Rt-21 deg C) To (Rt+25 deg C), * Mtp (Rt-15 deg C) To (Rt+20 deg C)
Catalog Number: 76493-128
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5110 Pump With Automatic Purge ValveAccuracy +/- 1% Or +/- 2 ul/Min, Whichever Is Greater (0.010 To 5.000 Ml/Min)Precision +/- 0.075 % Rsd Or 0.02 Min Sd Maximum Pressure 40 Mpa (0.001 To 5.000 Ml/Min), 20 Mpa (5.001 To 9.999 Ml/Min)
Catalog Number: 76493-060
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Chromaster 5310 Column Oven, Range: [Room Temperature - 15 deg C] To [Room Temperature + 60 deg C], Setting Range: 1 To 85 deg C, Accuracy: +/- 1 deg C, Temp Control Precision: Sd 0.2 deg C, Column Capacity: 3 Each 300Mm Columns, Safety: Built-In Vapor/Leak Sen
Catalog Number: 76493-132
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Sample Loop, For 5210/5260, Injection Volume: Maximum 2000Ul (Cut Method)
Catalog Number: 76493-126
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Manual Injection Holder, Required in Case Column Oven is Not Configured
Catalog Number: 76493-080
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Flow Cell(path: 5mm, vol.: 3.2ul, pressure:1.0MPa), semi micro, For 5410/5420
Catalog Number: 76493-164
Supplier: HITACHI HIGH-TECH AMERICA, INC.


Description: Ui Pad For 5410/5420 Uv/Uv-Vis Detector. Mounting Parts Kit Are Included.
Catalog Number: 76493-198
Supplier: HITACHI HIGH-TECH AMERICA, INC.