You Searched For: RealDolmen NV/SA


919  results were found

Sort Results

List View Easy View (new)
SearchResultCount:"919"
Description: ASTM size: 350. Approximate constant: 0.5. Kinematic Viscosity Range: 100 to 500 centistokes. For measuring kinematic viscosity of petroleum products. Minimum sample volume: 7mL. Require liquid bath depth of 203mm.
Catalog Number: 47734-942
Supplier: Cannon


Description: BS/U/M Miniature Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume: 2 ml, Minimum bath depth: 9 in, Size M2, Approx. constant of 0.005 cSt/s. Viscosity range 1 - 5 cSt.
Catalog Number: 10791-266
Supplier: Cannon


Description: Viscometer, Zeitfuchs Transparent with rectangular holder, measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104, Minimum sample volume: 15 mL, Minimum bath depth: 11.5 in. Size 5, constant 0.3 cSt/s. Viscosity range: 60 - 300 cSt
Catalog Number: 10791-126
Supplier: Cannon


Description: Viscometer, Zeitfuchs Transparent with round holder, measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104, Minimum sample volume: 15 mL, Minimum bath depth: 11.5 in. Size 1 approximately, constant 0.003 cSt/s. Viscosity range: 0.6 - 3 cSt
Catalog Number: 10791-090
Supplier: Cannon


Description: Viscometer, Zeitfuchs Transparent with round holder, measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104, Minimum sample volume: 15 mL, Minimum bath depth: 11.5 in. Size 7 approximately, constant 3 cSt/s. Viscosity range: 600 - 3000 cSt
Catalog Number: 10791-116
Supplier: Cannon


Description: Viscometer, Zeitfuchs Transparent with round holder, measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104, Minimum sample volume: 15 mL, Minimum bath depth: 11.5 in. Size 1 approximately, constant 0.003 cSt/s. Viscosity range: 0.6 - 3 cSt
Catalog Number: 10791-104
Supplier: Cannon


Description: Viscosity Standard, N415, General Purpose, used for calibration and verification procedures for all types of viscometers, including glass capillary viscometers, rotational viscometers, falling ball viscometers, cup viscometers, meet the precision specifications ASTM D 445/446, 5 gallon.
Catalog Number: 10021-258
Supplier: Cannon


Description: Cold-Cranking Simulator Standard, CL170, used for calibration and verification procedures for all types of viscometers, including glass capillary viscometers, rotational viscometers, falling ball viscometers, cup viscometers, meet ASTM D 5293 and SAE Specification J300, 5 gallon.
Catalog Number: 10021-556
Supplier: Cannon


Description: Cold-Cranking Simulator Standard, CL120, used for calibration and verification procedures for all types of viscometers, including glass capillary viscometers, rotational viscometers, falling ball viscometers, cup viscometers, meet ASTM D 5293 and SAE Specification J300, 5 gallon.
Catalog Number: 10021-516
Supplier: Cannon


Description: Viscosity Standard, N415, General Purpose, used for calibration and verification procedures for all types of viscometers, including glass capillary viscometers, rotational viscometers, falling ball viscometers, cup viscometers, meet the precision specifications ASTM D 445/446, 1 L
Catalog Number: 10021-254
Supplier: Cannon


Description: Cold-Cranking Simulator Standard, CL300, used for calibration and verification procedures for all types of viscometers, including glass capillary viscometers, rotational viscometers, falling ball viscometers, cup viscometers, meet ASTM D 5293 and SAE Specification J300, 4L
Catalog Number: 10021-656
Supplier: Cannon


Description: Silicone Viscosity Standard, RT100000, Intended for calibration of Brookfield type rotational viscometers. Actual viscosity data at 20 deg C, 23 deg C, 24 deg C, 25 deg C, 26 deg C, 27 deg C, and 40 deg C is provided on the Certificate of Analysis. Meets ISO 9001. 1L
Catalog Number: 10021-920
Supplier: Cannon


Description: Silicone Viscosity Standard, RT10, Intended for calibration of Brookfield type rotational viscometers. Actual viscosity data at 20 deg C, 23 deg C, 24 deg C, 25 deg C, 26 deg C, 27 deg C, and 40 deg C is provided on the Certificate of Analysis. Meets ISO 9001. 1L
Catalog Number: 10021-860
Supplier: Cannon


Description: Viscosity Standard, N750, General Purpose, used for calibration and verification procedures for all types of viscometers, including glass capillary viscometers, rotational viscometers, falling ball viscometers, cup viscometers, meet the precision specifications ASTM D 445/446, 5 gallon.
Catalog Number: 10021-276
Supplier: Cannon


Description: Cold-Cranking Simulator Standard, CL120, used for calibration and verification procedures for all types of viscometers, including glass capillary viscometers, rotational viscometers, falling ball viscometers, cup viscometers, meet ASTM D 5293 and SAE Specification J300, 1 L
Catalog Number: 10021-512
Supplier: Cannon


Description: Cold-Cranking Simulator Standard, CL160, used for calibration and verification procedures for all types of viscometers, including glass capillary viscometers, rotational viscometers, falling ball viscometers, cup viscometers, meet ASTM D 5293 and SAE Specification J300, 0.5L
Catalog Number: 10021-540
Supplier: Cannon


17 - 32 of 919