You Searched For: large centrifuge


916  results were found

Sort Results

List View Easy View (new)
SearchResultCount:"916"
Description: Sorvall BIOS 16 centrifuge, ACE Integrator, Pre-Cooling Function, Heat Output: < 2 kW, Imbalance tolerance: 125g in opposite loads, Maximum speed: 5,400rpm, Maximum RCF: 8,500 x g, Run time: 99 hours 59 min 59 sec, Dimension: 39.9x32.Bios 16 1x35.4in, Size: 8x2000mlSorvall
Catalog Number: 76302-936
Supplier: Thermo Scientific

Irregular Voltage


Description: Sorvall BIOS A centrifuge, 200, 208, 220, 230, 240 V +/-10%, 60 Hz, Single phase; 200 V, 50 Hz Japan only, Centri-Touch touchscreen Interface, Heat Output: 2.3 KW/h, Max speed: 6,250rpm, Max RCF: 12,000 x g, Dimension: 1015 x 816 x 990mm, Size: 10x1000ml
Catalog Number: 76302-940
Supplier: Thermo Scientific

Irregular Voltage


Description: Sorvall BIOS A Heavy Duty centrifuge, 200, 208, 220, 230, 240 V +/-10%, 60 Hz, Single phase; 200 V, 50 Hz Japan only, Pre-Cooling Function, Max Speed: 6,250rpm, Max RCF: 12,000 x g, Heat Output: 2.3 KW/h, Dimension: 1015 x 816 x 990 mm, Size: 10x1000 mL
Catalog Number: 76302-942
Supplier: Thermo Scientific

Irregular Voltage


Description: For determining the hematocrit value.
Catalog Number: 93001-774
Supplier: VWR International


Description: 18 x 1.5ML. For use with Clinical 200 Centrifuge. Max. speed 6,000rpm / 2,455 x g.
Catalog Number: 93001-770
Supplier: VWR International


Description: For six 50mL tubes. For use with VWR* Clinical 200 Centrifuges 82017-654, -656, 82013-812, and -814. Maximum speed: 6000rpm. Maximum RCF: 3823g.
Catalog Number: 82013-822
Supplier: VWR International


Description: For twelve 15mL tubes. For use with VWR* Clinical 200 Centrifuges 82017-654, -656, 82013-812, and -814. Maximum speed: 6000rpm. Maximum RCF: 4185g.
Catalog Number: 82013-816
Supplier: VWR International


Description: For six 5mL tubes. For use with VWR* Clinical 200 Centrifuges 82017-654, -656, 82013-812, and -814. Maximum speed: 3500rpm. Maximum RCF: 1420g.
Catalog Number: 82013-828
Supplier: VWR International


Description: For use with fixed-angle rotor 82013-816, used with VWR* clinical 200 centrifuges 82017-654, -656, 82013-812, and -814. Also for use with 6x15mL rotor included with VWR clinical 50 centrifuge 82013-800. Holds 5mL (12x75mm) or 7mL (13x100mm) tubes.
Catalog Number: 82013-820
Supplier: VWR International


Description: Centrifuge 5920R, Refrigerated, Keypad, Without rotors, Extraordinary high capacity and performance, Swing-bucket rotors and adapters, Fixed-angle rotors, Aerosol-tight caps, For high-throughput applications, Speed: 25062 x
Catalog Number: 75874-302
Supplier: Eppendorf


Description: Centrifuge 5920 R, Refrigerated, With Rotor S-4x1000, Keypad, High-capacity buckets and adapters for 15 mL/50 mL conical tubes, Cell culture pack, Power: 120V/50-60Hz, Maximum capacity of conical tubes per rotor: 108x15ml/5
Catalog Number: 75874-304
Supplier: Eppendorf


Description: Cent5920R S-4X1000 Plate Carrier, Multipurpose Centrifuge with S-4x1000 Rotor. Includes plate/tube buckets and plate carrier. High throughput with felxibility based on sample containment.
Catalog Number: 76443-014
Supplier: Eppendorf


Description: Centrifuge, 5920R, Frequency: 50 – 60 Hz, Swing-bucket rotors and adapters accommodate tubes and bottles from 0.2 mL to 1,000 mL, Aerosol Tight Caps Included, Compact footprint saves valuable bench space, High centrifugation speed of up to 21,194 x g, Voltage: 120 V
Catalog Number: MP75874-302
Supplier: Eppendorf


Catalog Number: 470353-208
Supplier: MTC BIO, INC.


Catalog Number: 470353-204
Supplier: MTC BIO, INC.


Description: Centrifuge Tube, racked, sterile, made of strong medical grade polypropylene, Flat-top screw on caps are made of highdensity polyethylene, Large white writing area with graduations printed in 1mL increments, Gamma radiation sterilized, nonpyrogenic, withstand centrifugation of 12,500 RCF, Size: 50ml
Catalog Number: 76469-334
Supplier: Tradewinds Direct


17 - 32 of 916