MEPS™ Syringes and Barrel Insert and Needle Assemblies (BINs), SGE

Supplier: Trajan Scientific and Medical
Ratings: (No Reviews)

Total Ratings: 0
Avg. Ratings: 0.0 out of 5

005291 006291 006292 2900701 2900702 2900703 2900705 2900706 2900707 2900711 2900712 2900713 2900715 2900716 2900717
97003-477EA 195.52 USD
97003-477 97003-478 97003-479 97003-480 97003-481 97003-482 97003-483 97003-484 97003-485 97003-486 97003-487 97003-488 97003-489 97003-490 97003-491 97003-492 97003-493 97003-494 97003-495 97003-496 97003-497 97003-498 97003-499 97003-500 97003-501 97003-502 89205-440 89205-442 89205-444 89205-544 89205-546 76409-366 76409-368 76409-370 76409-372 76409-374 76409-376 76409-378 76409-380 76409-382 76409-384 76409-386 76409-388
MEPS™ Syringes and Barrel Insert and Needle Assemblies (BINs), SGE
Syringes Syringes for Chromatography
Micro Extraction by Packed Sorbent (MEPS) is a new method of sample preparation that performs the same function as SPE, but works with much smaller sample volumes than full-scale SPE, can be fully automated, and uses the same syringe for sample processing, extraction, and injection steps performed on-line. The MEPS system consists of a MEPS syringe and the MEPS Barrel Insert and Needle Assembly (BIN). The BIN contains the SPE phase, and is built into the syringe needle. When the BIN is exhausted, or another phase is required, the BIN is easily removed and replaced.

Sample volumes as small as 10µL can be used, or larger samples can be concentrated by taking multiple aliquots of 100 or 250µL

MEPS procedures are suitable for reversed phases, normal phases, mixed mode, and ion exchange chemistries. Syringes may be used manually. No mount modifications are required when used with Thermo Scientific and CTC Analytics auto-injectors.

The ability to prepare and inject samples on-line using a single device reduces processing time and the need for operator intervention. Typical BIN lifespan is 40–100 samples, depending on the sample matrix. The small quantity of phase in the MEPS BIN can be washed between samples to eliminate the possibility of carry-over. BINs are available in a variety of common SPE phases. Dimensions of the sorbent bed ensure that the sorbent performance remains identical to conventional SPE devices used for extraction of similar samples. Sample preparation for complex biological samples can be adapted to MEPS.

Ordering information: MEPS Development Kits include one each of C18, silica, C8+SCX, C2, and C8 BINS. MEPS BIN orders include syringe needles packed in a sealed blister pack to preserve integrity.
Order Now

Learn more

About VWR

Avantor is a vertically integrated, global supplier of discovery-to-delivery solutions for...

Learn more About VWR