You Searched For: Acetonitrile : Water

Calibrated with clear markings, the capillary viscometers support visual viscosity measurements of liquids. The direct or reverse flow styles have respectively positioned reservoirs to calculate the time it takes a specific fluid quantity to flow through the capillary. Since the driving force is gravity and cannot be varied, the standardized glass tubes produce more reliable results. Common Ostwald and Ubbelohde capillary viscometers are inexpensive alternatives to digital versions when determining material properties.

Calibrated with clear markings, the capillary viscometers support visual viscosity measurements of liquids. The direct or reverse flow styles have respectively positioned reservoirs to calculate the time it takes a specific fluid quantity to flow through the capillary. Since the driving force is gravity and cannot be varied, the standardized glass tubes produce more reliable results. Common Ostwald and Ubbelohde capillary viscometers are inexpensive alternatives to digital versions when determining material properties.


451  results were found

SearchResultCount:"451"

Sort Results

List View Easy View (new)

Rate These Search Results

Catalog Number: (10791-406)
Supplier: Cannon
Description: 6810107


Catalog Number: (10791-414)
Supplier: Cannon
Description: Cannon Modified Koppers Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 2 mL. Minimum bath depth is 7 in. Size 400. Approximate constant is 500 poise/second at 300 mm. Viscosity range is 9600 - 200000 poise.


Catalog Number: (10791-080)
Supplier: Cannon
Description: Viscometer, Ubbelohde Dilution, measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104, Minimum sample volume: 8 mL, Minimum bath depth: 12 in. Size 350 approximately, constant 0.5 cSt/s. Viscosity range: 100 - 500 cSt


Catalog Number: (10791-048)
Supplier: Cannon
Description: Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Min sample vol: 8 mL. Min bath depth: 12 in. Size 100. Approx. constant 0.015 cSt/s. viscosity range 3 - 15 cSt.


Catalog Number: (10791-078)
Supplier: Cannon
Description: Viscometer, Ubbelohde Dilution, measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104, Minimum sample volume: 8 mL, Minimum bath depth: 12 in. Size 300 approximately, constant 0.25 cSt/s. Viscosity range: 50 - 250 cSt


Catalog Number: (10791-072)
Supplier: Cannon
Description: Viscometer, Ubbelohde Dilution, measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104, Minimum sample volume: 8 mL, Minimum bath depth: 12 in. Size 100 approximately, constant 0.015 cSt/s. Viscosity range: 3 - 15 cSt


Catalog Number: (10791-052)
Supplier: Cannon
Description: Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Min sample vol: 8 mL. Min bath depth: 12 in. Size 200. Approx. constant 0.1 cSt/s. viscosity range 20 - 100 cSt.


Catalog Number: (10791-082)
Supplier: Cannon
Description: Viscometer, Ubbelohde Dilution, measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104, Minimum sample volume: 8 mL, Minimum bath depth: 12 in. Size 400 approximately, constant 1.2 cSt/s. Viscosity range: 240 - 1200 cSt


Catalog Number: (10791-066)
Supplier: Cannon
Description: Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Min sample vol: 8 mL. Min bath depth: 12 in. Size 25. Approx. constant 0.002 cSt/s. viscosity range 0.5 - 2 cSt.


Catalog Number: (10791-046)
Supplier: Cannon
Description: Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Min sample vol: 8 mL. Min bath depth: 12 in. Size 75. Approx. constant 0.008 cSt/s. viscosity range 1.6 - 8 cSt.


Catalog Number: (10791-412)
Supplier: Cannon
Description: Cannon Modified Koppers Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 2 mL. Minimum bath depth is 7 in. Size 200. Approximate constant is 128 poise/second at 300 mm. Viscosity range is 2400 - 52000 poise.


Catalog Number: (10791-056)
Supplier: Cannon
Description: Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Min sample vol: 8 mL. Min bath depth: 12 in. Size 350. Approx. constant 0.5 cSt/s. viscosity range 100 - 500 cSt.


Catalog Number: (10791-058)
Supplier: Cannon
Description: Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Min sample vol: 8 mL. Min bath depth: 12 in. Size 400. Approx. constant 1.2 cSt/s. viscosity range 240 - 1200 cSt.


Catalog Number: (10791-050)
Supplier: Cannon
Description: Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Min sample vol: 8 mL. Min bath depth: 12 in. Size 150. Approx. constant 0.035 cSt/s. viscosity range 7 - 35 cSt.


Catalog Number: (10791-060)
Supplier: Cannon
Description: Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Min sample vol: 8 mL. Min bath depth: 12 in. Size 450. Approx. constant 2.5 cSt/s. viscosity range 500 - 2500 cSt.


Catalog Number: (10791-042)
Supplier: Cannon
Description: Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Min sample vol: 8 mL. Min bath depth: 12 in. Size 25. Approx. constant 0.002 cSt/s. viscosity range 0.5 - 2 cSt.


Inquire for Price
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at 1-800-932-5000.
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at 1-800-932-5000.
In order to process your orders without delay, we request that you provide the required business documentation to purchase this product.

To order chemicals, medical devices, or other restricted products please provide identification that includes your business name and shipping address via email CMD_NA@vwr.com or fax 484.881.5997 referencing your VWR account number . Acceptable forms of identification are:

  • State issued document with your organization's Federal Tax ID Number
  • State issued document with your organization's Resale Tax ID Number
  • City or County issued Business License
  • State Department of Health Services License
  • Any other ID issued by the State that includes the business name and address

* Please note if your account is within the State of California two of these pieces of identification will be required.
VWR will not lift restrictions for residential shipping addresses.

-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
This product has been blocked by your organization. Please contact your purchasing department for more information.
The original product is no longer available. The replacement shown is available.
This product is no longer available. Alternatives may be available by searching with the VWR Catalog Number listed above. If you need further assistance, please call VWR Customer Service at 1-800-932-5000.
49 - 64 of 451
no targeter for Bottom